User`s guide
RA8000/ESA12000 HSG80 Solution Software V8.5 for Sun Solaris
Page 28 387372-005 AA–RFBPE–TE
10.5 Uninstall Notes
Command Console Client Uninstall Does Not Remove AsyncEventService
Entries
Before uninstalling the Command Console Client, first remove the
AsyncEventService entries. This prevents the computer from sending you
messages during boot time about a service failing to start.
Under Windows 95 and Windows 98, go into Control Panel | Async Event
Service and uncheck "Automatic startup on boot." Under Windows NT, change
to the directory to which you installed the Command Console Client, type the
following command and then press RETURN:
AsyncEventService -remove
Then, remove the Command Console Client.
10.6 Clarifications
This section presents clarifications on the behavior of the software in certain
situations.
Integration Problems with SWCC and Insight Manager
Starting with Insight Manager version 4.23, the HSG80 controller can be
monitored and managed from Insight Manager. Insight Manager includes the
HSG80 controller and its status on the Insight Manager storage display. Insight
Manager can also launch the SWCC HSG80 Storage Window to manage storage
connected to the HSG80 controller.
When the HSG80 Storage Window is opened within Insight Manager, the
Storage Window that supports ACS version 8.4 and earlier is launched. The
Storage Window will work correctly as long as it is used with HSG80 controllers
that have ACS 8.4 or earlier. The HSG80 Storage Window that opens within
Insight Manager does not support ACS 8.5 or later. Undesirable results may
occur if this Storage Window is used with HSG80 controllers that have ACS 8.5
or later.