User`s guide

RA8000/ESA12000 HSG80 Solution Software V8.5 for Sun Solaris
Page 26 387372-005 AARFBPETE
10.3 Qualification
Client has been qualified with the operating systems, platforms, and controllers
shown in Table 4:
Table 4 Client Operating System and Platform Qualification
Operating System Platforms Tested On Controller
Microsoft
®
Windows
NT
®
, version 4.0
(with Service
Pack 5)
Windows 95
Windows 98
(Service Pack 1)
DEC Prioris ZX 6000
DEC Prioris ZX 5200
DEC DECps XL 466d2
DEC AlphaStation 500 333
Compaq Professional
Workstation AP400
Emulex
®
LP6000/7000 host
adapters with version 4.00A4
PCI driver
HSG80
controller/version 8.5
software
10.4 Installation Notes
Client Installation Claims System Files Are Out-of-Date, Even After
Installing New Files
SWCC 2.x Client software requires at least version 2.20.0.0 of Microsofts
OLEAUT32.DLL file. If the version installed is older than version 2.20.0.0, the
SWCC installation will show a dialog box with the following information:
Systems files are out-of-date.
It will install new system files.
Rerun the installation after the system reboots.
With some versions of OLEAUT32.DLL, the version check will fail and
InstallShield will not overwrite with the newer file. This action will cause the
install to always say that the system files need to be upgraded and to never allow
you to install SWCC. To fix this, ensure that a proper version of
OLEAUT32.DLL was installed by installing a clean version of the operating
system.