User`s guide

RA8000/ESA12000 HSG80 Solution Software V8.5 for Sun Solaris
Page 22 387372-005 AARFBPETE
8.3 Adding, Moving, and Changing Controllers, Cache Modules, or
External Cache Batteries
It is permissible to replace the controller, cache module, or external cache battery
while the subsystem is shut down. However, you must enter the SHUTDOWN
THIS_CONTROLLER command before shutting the subsystem down to make
configuration changes. If two controllers are configured in a dual-redundant
configuration, you must first enter the SHUTDOWN OTHER_CONTROLLER
command.
These commands instruct the controllers to flush all unwritten data from the
cache modules and discontinue all I/O activity. For more information regarding
the SET controller command or maintenance and replacement of the controller,
cache module, and external cache battery, see the HSG80 Array Controller ACS
Version 8.5 Configuration Guide and the HSG80 Array Controller ACS Version
8.5CLI Reference Guide.
8.4 Establishing a SWCC Direct Connection
If the first attempt to establish a SWCC SCSI or serial direct connection fails, try
making the connection again.
9.0 DOCUMENTATION ADDITIONS AND CORRECTIONS
The following corrections are for the HSG80 Array Controller ACS Version 8.5
Maintenance and Service Guide.
Add the following part numbers to Table 1-1, The HSG80 Subsystem:
Table 1-1 The HSG80 Subsystem
Item Description Part Number
2 Cooling fan, gray 402602-001
14 Disk drive, 4 GB, 7200
Disk drive, 9 GB, 7200
Disk drive, 18 GB, 7200
Disk drive, 9 GB, 10K
Disk drive, 18 GB, 10K
402153-001
400289-001
400290-001
402154-001
402229-001
Add the following part numbers to Table 1-2, HSG80 Fibre Channel Array
Controller: