Installation guide

27
Reset Cable Kits and Installation
%
DIGITAL Server Systems
DIGITAL Prioris XL Server
Kit PN: FR-PCXCK-AB
Connect the reset cable to the controller (
F
on Figure 1) and to the pins labeled
RSM Conn (J40)
on the main logic board. This 3-pin connector is located on the
right-hand edge of the main logic board directly across from EISA slot 1. Pin 1 is
on the left. Refer to the server user’s guide if you need further assistance in
locating the connector.
DIGITAL Prioris HX 590 and 590DP
Kit PN: FR-PCXCK-AE
Connect the interconnect cable to the controller (
F
on Figure 1) and to the 12-pin
connector
DSM Conn (J40)
on the main logic board. Also, remember to remove
jumper
J42
.
DIGITAL Prioris HX 5100MP
Kit PN: FR-PCXCK-AE
Connect the interconnect cable to the controller (
F
on Figure 1) and to the 12-pin
connector
DSM Conn (J40)
on the main logic board. Also, remember to remove
jumper
J42
.
DIGITAL Prioris ZX 5000MP
Kit PN: FR-PCYCK-AF
Connect the interconnect cable to the controller (
F
on Figure 1) and to the 12-pin
connector
J18
on the fan and control board. Also, remember to remove jumper
J19
.