Technical data
6 MD400 Scanner Pocket Service Guide
6. Read the installation procedures in the
IS50/DF60 User Manuals.
NOTE
The power cord is shipped as a separate
line item, not with the scanner (as shown
in the IS50 User Manual).
7. VAXstation users should halt the system and
use the console command:-
>>> SHOW DEVICES
to display the current status of SCSI IDs.
Determine and note a suitable SCSI ID for
the scanner; an ID of zero is recommended if
available.
8. Switch off the power to the system box and all
peripherals.
WARNING
Before connecting or disconnecting
interface cables, remove power from
the scanner, the host computer and any
other devices connected to the SCSI bus.
WARNING
A special interface cable is supplied in
the PC interface kit. Do not use any
other cable for this purpose as this may
severely damage equipment.
9. Install the interface kit to connect the
computer to the scanner as follows:
• VAXstation - I/F cables and terminator,
refer to the 3100 User Manual.
• DECstation - I/F card and cable, refer to
the ISI-8 Installation Manual.