Specifications

Table 5–2: Diagnostic Self-Test Sequence
Test
No.
Error
Code
FRU
Tested
Test
No.
Error
Code
FRU
Tested
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
529
547-549
530
529
020
022
544
050
055
080
531
060
inF
700
i20-i22
i13
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSM
SMSI
SMIM
SMIM
SMIM
17
18
19
20
21
22
23
24
25
26
27
I25-I32
420
440
i33
i14
490
"
"
491
"
"
493
494
"
Ac1-Ac3
SMIM
SMIM
SMIM
SMIM
SMIM
SMIH
SMMC
LVT
SMIH
SMMC
LVT
SMIH
SMIH
SMIH
PAM†
SHAD
†PAM=Print Actuator Module 1, 2, or 3
5.2.3 Error Codes
There are two types of error codes displayed by the printer:
1. Self-Test Error Codes—These error codes are displayed if a problem
occurs during the diagnostic self-test.
2. Run Time Error Codes—These error codes are displayed if (1) an
operator correctable fault occurs, or (2) a fault occurs that may affect
operation but not require corrective action. The operator information
error codes can be displayed at any time; however, the self-test error
codes take precedence over them at power-up, and after the ASCII
print test is terminated.
Table 5-3 lists, in alphanumeric order, both types of error codes the
printer displays, lists the FRU involved in the test, lists the removal and
replacement procedure for the affected FRU, and describes the failure.
5–8 TROUBLESHOOTING