Specifications
Figure 7–5: Horizontal Timing Pattern Sample Printouts
RE7585
A. Key 5: Horizontal Timing Pattern No. 1. Normal, no adjustment required.
B. Key 5: Horizontal Timing Pattern No. 2. Left inner line uneven; right inner line straight.
To correct, adjust R26 on SMIH board counterclockwise.
C. Key 5: Horizontal Timing Pattern No. 3. Left inner line straight; right inner line uneven.
To correct, adjust R26 on SMIH board clockwise.
PRINT QUALITY ADJUSTMENT PROCEDURES 7–13