Specifications
7.5.3 Horizontal Timing Pattern Adjustment Procedure
1. Press the CPI LPI (5) key and observe that the printer display
changes to [.H E P]. The Horizontal Timing Pattern is printed.
Figure 7–4A representts a magnified view of three of the 33 bar
pattern that is actually printed. Press the FCT (9) key to stop
printing the pattern; press the FCT (9) key again to resume printing
the same pattern.
2. If the printout is not the same as Figure 7–4A, follow the instruc-
tions given with the figure (Figure 7–4B or C) that matches your
printout. When the adjustments have been made to produce the
printout shown in Figure 7–4A, proceed to Intermodule Gap Pattern
Adjustment (see Section 7.5.4).
7–12 PRINT QUALITY ADJUSTMENT PROCEDURES