Operator`s manual

Table 4–2 (Cont.): Serial Interface Strapping Options
Strap
Number Action When In (In = 1; Out = 0)
A26 Enable transmission of an <ACK> on receipt of an <ETX>
A27 Reverse SCA polarity (active state LOW) if SCA is enabled
A28 Reverse DTR polarity (active state LOW) if DTR is enabled
A29 Inhibit received parity check
A30 Enable two stop bits
A31 Enable transmitter
OTHER
A32 Reverse CA polarity (active state LOW) if CA is enabled
B1 Not assigned
B2 No parity bit transmitted/received
B3 Enable auto input buffer expansion
B4 Host may not use CC to inhibit transmit
B5 Replaces underline character with <CR>
B6 Seven and eight bit data accepted
B7-B32 Not assigned
NOTE
The configuration menu prints out strap status in serial inter-
face in two rows A1-A32 and B1-B32. The LED display, how-
ever, shows 1 through 64 with 33-64 being equivalent to B1-
B32.
4.4 Print Characteristics
The rest of the configuration entries control the form and location of the
printed data.
4.4.1 Font
Under the font category in the program mode, there are six subcategories
(see Figure 4–8):
1. Style - the quality/density of the printed characters
2. CPI - Characters Per Inch
3. Country
4. Mode (there are no font enhancements available through the control
panel)
4–14 SETTING COMMUNICATIONS AND PRINT PARAMETERS