Operator`s manual
Table 7–6: Reset State Default Parameters
Selectable
Parameter Reset Default Condition
Print Status On-line (ready)
Horizontal Pitch 10 characters per 2.54 cm/in
Vertical Pitch 6 lines per inch
Font Data Processing
Forms Length 66 lines (11 inches/27.94 cm)
Active Position Column 1 on the current active line (line 1)
Top Margin Line 1
Bottom Margin Line 66
Left Margin Column 1
Right Margin Column 132
Underlining Disabled
Bolding Disabled
Italics Disabled
Character
Expansion
Disabled
GL Character Set U.S. ASCII or the last NCR if selected
GR Character Set Digital Supplemental
G0 Character Set U.S. ASCII or the last NCR if selected
G1 Character Set VT100 Graphic Character Set
G2 Character Set Digital Supplemental
G3 Character Set U.S. ASCII
Autowrap Enabled
Line Feed/New
Line Mode
Set
Horizontal tabs At every 8 columns (9, 17,..137)
Unsolicited reports Disabled
Super/Subscripts Disabled
Carriage Return
New Line Mode
Reset
Vertical Tabs Every line (1, 2, ... 66)
The following will not change:
All Interface settings
The National Replacement Character Set
Top and bottom margins
Left and right margins
These parameters will remain as previously selected, either by escape sequence
or control panel.
OPERATOR MAINTENANCE 7–9