Operator`s manual
Table 7–3: Factory Settings
Selectable Parameter Factory Set Condition
Print Status Off-Line
Horizontal Pitch 10 characters per 2.54 cm/in
Vertical Pitch 6 lines per inch
Font Data Processing
Forms Length 66 lines (11 in/27.94 cm)
Active Position Column 1, Line 1
Top Margin Line 1
Bottom Margin Line 66
Left Margin Column 1
Right Margin Column 132
Underlining Disabled
Bolding Disabled
Italics Disabled
Character Expansion Disabled
GL Character Set U.S. ASCII
GR Character Set Digital Supplemental
G0 Character Set U.S. ASCII
G1 Character Set VT100 Graphic Character Set
G2 Character Set Digital Supplemental
G3 Character Set U.S. ASCII
Autowrap Enabled
Line Feed/New Line
Mode
Set
Horizontal tabs At every 8 columns (9, 17,..137)
Unsolicited reports Disabled
Super/Subscripts Disabled
Carriage Return New
Line Mode
Reset
Vertical Tabs Every line (1, 2, ... 66)
Number of data bits 8-bit mode
Number of stop bits 1 stop bit
Speed (baud rate) 9600 baud
Parity Disabled
7.3.1 Power-Up Parameters Set
Table 7-4 lists the default conditions upon power-up of the LG31 printer.
7–6 OPERATOR MAINTENANCE