Specifications

Operating
System
Support
VMS
ULTRIX-32
VAXELN
Diagnostic
Support
MicroVAX Diagnostic Monitor
Self-tests
Related
Documentation
EK-AVllO-UG
Version
5.0-2Aand
later
using VAXlab Software
Library
Not supported
as
of
Version 3.0
Version 3.2
and
later
Revision 2.3
and
later
No
Q-Bus DMA Analog System User's Guide
2.3.7 KWV11-S Programmable Real-Time Clock
The
KWVll-S
is a programmable real-time clock
that
can
be programmed
to count from one to five crystal-controlled frequencies, from
an
external
frequency or event, or from a 50/60 Hz line frequency on
the
Q-bus.
The
board
can
generate
interrupts
or
can
synchronize
the
processor to
external
events.
The
KWVll-S
is functionally equivalent to a
KWVll-C.
Functional
Information
Resolution
Frequencies
Schmitt
Triggers
Input
Modes
16
bits
5
internal
crystal
frequencies-l
MHz, 100 kHz,
10 kHz, 1 kHz,
and
100 Hz
2, each
with
slope
and
level controls
that
can
be used to
start
the
clock
or
generate program
interrupts
Line frequency
input
from BEVNT
bus
signal
(50/60 Hz)
4 programmable modes
2-56
MicroVAX 3400 VAXserver 3400 Technical Information