September 1988 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.
Contents Preface vii Chapter 1 Base System Specifications 1.1 Base System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.1 Digital Small Storage Interconnect (DSSI). . . . . . . . . . . . . 1.1.2 KA640 Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. CPU Cover Panel Operation ...................... . 1.1.3 Switches .................................... . 1.1.3.1 LED Display ................................ . 1.1.3.2 Console Terminal Connector ................
Optical Disk Drives and Controllers ................. 2.1.3 2.1.3.1 KLESI Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . .. RV20 Optical Disk Drive. . . . . . . . . . . . . . . . . . . . . . .. 2.1.3.2 2.2 Communications Options. . . . . . . . . . . . . . . . . . . . . . . . . . .. 2.2.1 Asynchronous Serial Controllers. . . . . . . . . . . . . . . . . . .. 2.2.1.1 CXA16 Asynchronous Multiplexer (16 lines) ......... 2.2.1.2 CXB16 Asynchronou~ Multiplexer (16 lines) ......... 2.2.1.
( LP29 Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2.5.1.5 2.5.2 Dot Matrix Printers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2.5.2.1 LA75 Companion Printer. . . . . . . . . . . . . . . . . . . . . . .. 2.5.2.2 LA100 Letterwriter . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2.5.2.3 LA120 Printer!l'erminal (DECwriter III) . . . . . . . . . . .. 2.5.2.4 LA210 Letterprinter. . . . . . . . . . . . . . . . . . . . . . . . . . .. 2.5.
Preface This manual summarizes technical information about MicroVAX 3400 and VAXserver 3400 systems. The manual is organized as follows: • Chapter 1 describes the base system specifications, including the CPU module and associated memory options. • Chapter 2 describes specifications for optional components available for MicroVAX 3400 and VAXserver 3400 systems. • Chapter 3 contains information on expanding your system.
Chapter 1 Base System Specifications MicroVAX 3400 and VAXserver 3400 base system components reside in a BA213 enclosure, with a 12-slot backplane. The base system includes a central processor unit (CPU) module, and one to three memory modules. The CPU module resides in slot 1 of the backplane. Memory modules can reside in slots 2 through 4. 1.1 Base System Operation Base system operation is based on the KA640 CPU module.
The DSSI bus has the following characteristics: • 4 Mbytes-per-second bandwidth • Single-ended bus transfers • Up to eight nodes (up to two host adapters and six mass storage devices) • Eight data lines • One parity line • Eight control lines DSSI architecture features a DSSI host adapter and DSSI mass storage devices. The DSSI host adapter, located on the KA640 CPU module, is the interface between the DSSI mass storage devices and the CPU.
1.1.2 KA640 Firmware Two read-only memory (ROM) chips on the KA640 module contain firmware. The firmware contains three major programs: • A console program • A set of self-tests for the CPU and memory • A primary bootstrap program (VMB) The console program receives control whenever the processor halts. For the KA640 CPU, a halt means only that processor control has passed to the console program, not that instruction execution stops.
Ifthe self-tests are successful, the system does one of two things, depending on whether the Break EnablelDisable switch on the CPU cover panel is set to disable or enable. If the Break Enable/Disable Switch Is Disabled If the Break EnablelDisable switch is set to disable, the CPU tries to autoboot an operating system. It locates a 128-Kbyte segment of system memory and copies a primary bootstrap program, called VMB, from the ROM chip into the base address plus 512.
If the Break Enable/Disable Switch Is Enabled If break is enabled, the console program enters console I/O mode in response to any halt condition except the HALT instruction, including system powerup. Console I/O mode allows you to control the system by typing commands at the console terminal. CAUTION: Do not press the Restart button while in console mode. Doing so destroys the system state. You will not be able to continue normal operation.
• Ethernet logic which supports selection of the standard Ethernet port or the ThinWire port. 1.1.3.1 Switches The four switches on the CPU panel are the Break EnablelDisable switch, the Power-Up Mode switch, Ethernet connector switch, and the baud rate switch. The operation of these switches is discussed on the following pages. Figure 1-1: CPU Cover Panel ~LED BREAK ENABLE! DISABLE SWITCH ~. 6 .
Break Enable/Disable Switch (2-position slider) Switch Position Function Dot outside circle (down) Break disable (factory setting). With the switch in this position, pressing the iBreaki key on the console terminal has no effect on the system. On power-up or after a reset, the system attempts to load software from one of the boot devices at the completion of self-tests. Dot inside circle (up) Break enable. With the switch in this position, pressing the key on the console terminal halts the CPU.
Figure 1-2: Changing the Baud Rate BAUD RATE SELECT SWITCH ETHERNET HARDWARE ADDRESS o MLO-000692 1. Turn off the system and remove the front panel of the enclosure. 2. Using a Phillips-head screwdriver, push in and turn counterclockwise the quarter-turn screws at the top and bottom of the CPU cover panel until the screws pop free. 3. Place one hand at the top ofthe panel, and carefully pull out the bottom of the panel with the other hand. 4.
5. Tilt the top of the panel out as far as possible. The baud rate switch, a white circular switch, is just inside the top of the panel. A number from 0 to 7 is visible. See Table 1-'2 to determine the correct switch setting for the baud rate you want. Rotate the switch to the desired setting. Table 1-2: Baud Rate Switch Settings Setting Baud Rate 0 300 1 600 2 1200 3 2400 4 4800 5 96001 6 19200 7 38400 1Factory setting 6.
1.1.3.3 Console Terminal Connector The console cable is connected to the CPU cover panel through a modified modular jack (MMJ). An internal cable connects the MMJ, switches, and LED display to the CPU module. 1.1.3.4 Battery Backup Unit (BBU) A battery backup unit (BBU), located on the inside of the CPU cover panel, maintains the correct time-of-year and language selection on the CPU module when power to the system is turned off. Both the time-of-year and language selection code are lost if the BBU fails.
/ Central Processor Specification PDP-ll compatibility mode Emulated in software Time bases Time-of-year clock: 1 (battery backed up) i \ Interval timer: 1 (10 milliseconds) Programmable timers: 2 110 bus interface One Q22-bus interface with 8192 entry "scatter gather" map registers Termination 240n Memory Management and Control Page size 512 bytes Virtual address space 4 gigabytes Physical memory space 28 Mbytes Number of memory modules 3 maximum Performance Specification Instructio
Performance Specification Maximum 110 bandwidth DMARead 2.4 Mbytes/second DMA Write 3.3 Mbytes/second Ethernet Port Specification Supported protocols Ethernet V2.
Configuration Information Form factor Quad height Power requirements +5 Vdc, 6.0 A +12 Vdc, 0.24 A Power consumption 32.88 W Bus loads 3.5 ac 1.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes Related Documentation EK-KA640-TM KA640 CPU Module Technical Manual 1.2.
Performance Synchronous longword read 400 nanoseconds Synchronous unmasked longword write 200 nanoseconds Synchronous masked longword write 500 nanoseconds Synchronous quadword read 600 nanoseconds Ordering Information MS650-AF 8-Mbyte field-installed kit i Configuration Information Form factor Quad height Power requirements +5 Vdc, 2.7 A +12 Vdc, 0.0 A Power consumption 13.5 W Bus loads 0.0 ac 0.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.
Chapter 2 Option Specifications This chapter describes the options currently available for MicroVAX and VAXserver 3400 systems. Some of the options described are already installed. If you want to add other options to your system, your DIGITAL sales representative can advise you. Chapter 3 offers some guidelines on determining what options you can add to your system. Options must be properly configured so that the system recognizes them.
• Diagnostic support • Related documentation 2.1 Mass Storage Options MicroVAX and VAXserver 3400 systems have the following mass storage options: • RF30 fixed-disk drive • TK70 tape drive • TK50 tape drive • TS05 tape drive (in auxiliary cabinet only) • RV20 optical disk drive (in auxiliary cabinet only) Each drive has a controller that directs its activity. 2.1.1 Disk Drives and Controllers Up to three RF30 disk drives can be mounted in the MicroVAX or VAXserver 3400 system.
Storage capacity User capacity 150 Mbytes User capacity (blocks) 293,040 Physical Specifications Width 14.60 cm (5.75 in) Depth 20.45 cm (8.25 in) Height 4.40 cm (1.75 in) Weight 1.81 kg (4.0 lb) Configuration Information Form factor Standard 5.25-in footprint Power requirements +5 Vdc, 1.10 A +12 Vdc, 0.80 A Power consumption 15.1 W Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.
2.1.2 Tape Drives and Controllers MicroVAX and VAXserver 3400 systems support the following tape drives (and their controllers): • TS05 tape drive (in auxiliary cabinet only) • TK70 tape drive • TK50 tape drive 2.1.2.1 TSV05 Controller The TSV05 tape drive controller is used to interface the TS05 tape drive.
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Not supported as of Version 3.2 Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-TSV05-UG TSV05 Tape Transport System User's Guide 2.1.2.2 TS05 Tape Drive The TS05 is a one-half-inch reeI-to-reeI streaming tape drive. The drive has a maximum capacity of 40 Mbytes, using the industry-standard PE format.
Performance Handling Bidirectional reel-to-reel with compliance arm Tape velocity 64 or 254 cm/second (25 or 100 in/second) Maximum data transfer rate 40 or 160 Kbytes/second Rewind time (731 m (2400 ft) tape on 26.7 cm (10.5 in) reel) 2.8 minutes Physical Specifications Height 22.2 cm (8.75 in) Width 43 cm (17 in) Depth 62 cm (24.5 in) Weight 36 kg (80 lb) Configuration Information Form factor 10.5-in high, full rack width Operating System Support VMS Version 5.
2.1.2.3 TQK70 Controller The TQK70 controller module provides the interface between the TK70 tape drive and the Q22-bus. The controller uses the Tape Mass Storage Control Protocol (TMSCP).
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes 2.1.2.4 TK70 Tape Drive The TK70 is a streaming tape drive subsystem that can store up to 296 Mbytes on a tape cartridge for backup data storage. The TK70 can read data from cartridges recorded on a TK50 drive, but cannot write data to cartridges recorded on a TK50 drive.
Physical Specifications Depth 21.44 cm (8.44 in) Weight 2.27 kg (5.0 lb) Performance Tape start time 325 milliseconds maximum Tape stop time 200 milliseconds maximum Tape speed 390 cm/second (100 in/second) Streaming data rate 125 Kbytes/second Access time (from insertion of tape) TK50 mode (read-only) 35 minutes maximum TK70 mode 60 minutes maximum Configuration Information Form factor Standard 5.25-in footprint Power requirements +5 Vdc, 1.3 A +12 Vdc, 2.4 A Power consumption 35.
Related Documentation EK-OTK70-0M TK70 Tape Drive Subsystem Owner's Manual EK-OTK7D-TM TK70 Tape Drive Subsystem Technical Manual EK-OTK70-SM TK70 Tape Drive Subsystem Service Manual 2.1.2.5 TQK50 Controller The TQK50 controller module provides the interface between the TK50 tape drive and the Q22-bus. The controller uses the Tape Mass Storage Control Protocol (TMSCP).
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes 2.1.2.6 TK50 Tape Drive The TK50 is a streaming tape drive 3ubsystem that can store up to 95 Mbytes on a tape cartridge for backup data storage. Functional Information Recording media Magnetic tape Tape dimensions 1.27 cm (0.5 in) wide, 182.
Performance Tape start time 300 milliseconds maximum Tape speed 2925 cm (75 in)/second Streaming data rate 62 Kbytes/second Access time (from insertion of new tape) 35 minutes maximum Configuration Information Form factor Standard 5.25-inch footprint Power requirements +5 Vdc, 1.35 A +12 Vdc, 2.4 A Power consumption 35.6 A Bus loads 0.0 ac 0.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.
2.1.3 Optical Disk Drives and Controllers MicroVAX and VAXserver 3400 systems support the RV20 optical disk drive (and its controller). 2.1.3.1 KLESI Controller The KLESI controller is used to interface the RV20 optical disk drive.
Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-LESIB-UG KLESI-B Module User's and Installation Guide 2.1.3.2 RV20 Optical Disk Drive RV20 optical disk drives are available for MicroVAX and VAXserver 3400 systems. Up to four RV20 optical disk drives can be mounted in an auxiliary cabinet and connected to the MicroVAXlVAXserver 3400 system. The RV20 has a storage capacity of 1 gigabyte per side.
Physical Specifications Width 48.3 cm (19.0 in) Depth 65.0 cm (25.6 in) Height 13.0 cm (5.125 in) Weight 30.0 kg (60.0 lb) Configuration Information Form factor Rack-mountable Power requirements 88 to 132 Vac 176 to 264 Vac 50/60 ±3 Hz Power consumption (maximum) 200W Operating System Support VMS Version 5.0-2A and later ULTRIX-32 N/A VAXELN N/A Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
2.2 Communications Options Communications options supported by MicroVAX and VAXserver systems include asynchronous serial controllers, synchronous serial controllers, and a network controller. 2.2.1 Asynchronous Serial Controllers Asynchronous serial controllers provide low-speed connections between peripheral devices and the system. Asynchronous communications between the system and the peripheral depends on recognition of a pattern of start and stop bits, not on a time interval. 2.2.1.
Ordering Information CXAI6-AF CXA16 field-installed kit. Includes two 7.6m (25-ft) BC16D-25 cables, two H3104 cable concentrators, and other accessories required to install the option.
Performance Transmit buffer size One character for programmed transfers in DHV11 mode 64-character FIFO for programmed transfers in DHUll mode 64-character FIFO for DMA transfers in DHUll and DHV11 modes Receive buffer size 256-character FIFO in DHV11 and DHUll modes Supported baud rates 16 programmable baud rates: 50, 75, 110, 134.
Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes Related Documentation EK-CABI6-UG CXAI6/CXBI6 User's Guide EK-CABI6-TM CXAI61CXBI6 Technical Manual 2.2.1.2 CXB16 Asynchronous Multiplexer (16 lines) The CXB16 is an intelligent, preprogrammed, serial controller that can operate in either DHVll or DHUll mode, depending on the setting of an onboard switch.
Ordering Information CXB16-AF BC16E series cable H8572 Module and cable kit. Includes two 7.6-m (25-ft) BC16D-25 cables, two H3104 cable concentrators, and other accessories required to install the option. • BC16D-25 cable-data only, 36 conductor, terminated with 36-pin Amphenol male connectors • H3104 cable concentrator-concentrates eight BC16E cables into one BC16D cable; eight modified modular jacks and one 36-pin Amphenol female connector Office cable-data only, 6-conductor, terminated with.
Performance Supported baud rates 16 programmable baud rates: 50, 75, 110, 134.5, 150,300,600,1200,1800,2000,2400,4800,7200, 9600, 19200, 38400 1 Throughput at maximum baud rate: 5 data bits, 0 parity bits, 1 stop bit 140,000 characters/second (all lines) 7 data bits, 1 parity bit, 1 stop bit 110,000 characters/second (all lines) Configuration Information Form factor Quad height with integral, recessed cover panel Power requirements +5 Vdc, 1.4 A (typical) +12 Vdc, 0.
2.2.1.3 CXY08 Asynchronous Multiplexer (8 lines) The CXY08 can operate in either DHVll or DHUll mode, depending on the setting of an on-board switch. The CXY08 supports full modem control on all eight lines. Functional Information Supported line interfaces EIA RS-423-AlCCI'IT V.10 EIA RS-232-D/CCI'IT V.
Performance Transmit data transfers Single-character programmed transfers or up to 16-character block mode DMA transfers in DHV11 mode. Single-character or two-character programmed transfers, or up to 16-character block mode DMA transfers in DHU11 mode. Receive data transfers Single-character programmed transfers in both DHV11 and DHU11 modes.
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes Related Documentation EK-CXY08-UG CXY08 User's Guide EK-CXY08-TM CXY08 Technical Manual 2.2.1.4 DFA01 Asynchronous Controller with Integral Modem The DFAOI is an asynchronous serial controller that emulates the DZQll. It has two lines, each with a DF224-compatihle integral modem.
Functional Information Supported data formats Modem control 8 programmable formats (each with 1 start bit) • 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 1 stop bit • 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 2 stop bits Full Ordering Information DFAOl-AF DFA01 field-installed kit Performance Transmit data transfers Single-character programmed transfers Receive data transfers Single-character programmed transfers Transmit buffer size One character for programmed transfers Receive buf
Configuration Information Form factor Quad height with integral, flush cover panel Power requirements +5 Vdc, 1.97 A +12 Vdc, 0.40 A Power consumption 14.65 W Bus loads 3.0 ac 1.0 dc Module connectors 4 TELCO: 2 modified modular jacks (MMJ) for data lines; 2 modular jacks (MJ) for voice lines Operating System Support VMS Version 5.
Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Modem only Related Documentation EK-DFA01-UG DFA01 Modem User's Guide EK-DFA01-IN DFA01 Modem Installation Guide 2.2.1.5 CXF16 and CXF32 Asynchronous Controllers The CXFI6 and CXF32 are asynchronous multiplexers that provide fullduplex serial data channels on Q-bus systems. The CXFI6 supports one I6-line port. The CXF32 supports two I6-line ports.
Ordering Information CXFl6-AA 1 CXF32-M controller, 1 H3123-A terminal concentrator (120 Vacl, 1 BN25J-10 10-meter cable CXFl6-AB 1 ·CXF32-M controller, 1 H3123-B terminal concentrator (240 Vacl, 1 BN25J-10 10-meter cable CXF32-AA 1 CXF32-M controller, 2 H3123-B terminal concentrators (120 Vacl, 2 BN25J-10 10-meter cables CXF32-AB 1 CXF32-M controller, 2 H3123-B terminal concentrators (240 Vacl, 2 BN25J-10 10-meter cables Performance Transmit data transfers DMA or single-character programmed transf
Operating System Support VMS Version 4.6 and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes Related Documentation EK-DHFll-UG CXF16/CXF32 DHFllIH3123 User's Guide 2.2.1.6 DSRVB 'DECserver 200 The DEC server 200 is an 8-line terminal server used to connect terminals to a host computer on an Ethernet Local Area Network (LAN).
Ordering Information (hardware only)l DSRVB-AA 8-line DECserver 2001MC, RS232-C line interface, 120 V. Includes country kit. 2 DSRVB-BA 8-line DECserver 2001DL, DEC 423 (DECconnect) line interface, 120 V. Includes country kit. DSRVB-AB 8-line DECserver 2001MC, RS232-C line interface, 240 V. Requires country kit. DSRVB-BB 8-line DECserver 2001DL, DEC 423 (DECconnect) line interface, 240 V. Requires country kit. Performance Maximum throughput 8 lines at 19.
2.2.2 Synchronous Serial Controllers Synchronous serial controllers provide high-speed connections between systems. Communication between synchronous devices depends on time intervals that are synchronized before transmission of data begins. 2.2.2.1 DSV11 Synchronous Interface The DSVll provides two high-speed synchronous connections to DECnet, SNA, and X.25 networks. Functional Information Supported line interface EIA RS-232-C/CCITT Y.28 EIA RS-423-AlCCITT Y.10 X.26 EIA RS-422-AlCCITT y.n X.27 CCITT Y.
Ordering Information DSVll-SF DSVll field-installed kit. Includes BC19F adapter cable. Performance Transmit data transfers Block mode DMA transfers Programmed 110 for BISYNC protocol Receive data transfers Block mode DMA transfers TransmitlReceive buffer size Approx. 6.
Configuration Information Form factor Quad height with integral recessed cover panel Power requirements +5 Vdc, 6.5 A (typical) +12 Vdc, 0.875 A (typical) Power consumption 43.0W Bus loads 3.9 ac Module connectors 2 female 50-pin Amphenol connectors 1.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Not supported as of Version 3.0 VAXELN Not supported as of Version 3.2 Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
Functional Information Supported line interfaces EIA RS-232-C/CCITT V.24, V.28 CCITT V.351DDS EIA RS-423-A Supported protocol Digital Data Communications Message Protocol (DDCMP) in either point-to-point or multipoint mode Operating mode Full or half-duplex Modem support Full or limited Supported modems All DIGITAL modems and the Bell 200 series Ordering Information EIA RS-232-CI CCITT V.24, V.28 interface DMVll-SF DMVll field-installed kit BC19D-02 External modem cable CCITT V.
Configuration Information Form factor Quad height Power requirements DMVll-S +5 Vdc, 4.7 A (typical) +12 Vdc, 0.38 A (typical) Power consumption 28.1 W Bus loads 2.0 ac 1.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Not supported as of Version 3.2 Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
Functional Information Supported protocols Digital Data Communications Message Protocol (DDCMP) BISYNC SDLC Operating mode Full or half-duplex Character size Program selectable (5-8 bits with character-oriented protocols and lOS bits with bit-oriented protocols).
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Not supported as of Version 3.2 Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests None Related Documentation EK-DPVll-UG DPVll Synchronous Interface User's Guide EK-DPVll-TM DPVll Technical Manual 2.2.2.4 KMV1 A Programmable Communications Controller The KMVIA is a medium-speed, programmable data communications interface for Q-bus systems.
Performance Transmit buffer size 1032 bytes Supported baud rates 1200,2400,4800,9600,19200 Configuration Information Form factor Quad height Power requirements +5 Vdc, 2.6 A +12 Vdc, 0.2 A Power consumption 15.4 W Bus loads 3.0 ac 1.0 dc Module connectors One 25-pin D-type (RS-232) One 37-pin D-type (RS-422) One 37-pin D-type (RS-423) Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.
( 2.2.3 Network Controllers Network controllers connect your system to an Ethernet network. With a network connection and appropriate DECnet software, you can use all network services. NOTE: The MicroVAX 3400 and VAXserver 3400 systems include an Ethernet controller on the CPU module. One of the following controllers is only necessary if the system requires a second Ethernet connection. 2.2.3.
Configuration Information +12 Vdc, 0.22 A Power consumption 14.64 W Bus loads 3.3 ac 0.5 dc Module connectors (standard) One 15-pin D-type Module connectors (Thinwire) T-connector to BNC connector on DESQA Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests Yes Related Documentation EK-DESQA-TM DESQA Technical Manual 2.2.3.
Ordering Information DELQA-SF DELQA field-installed kit BNE3A-D External cable Performance TransmitlReceive data transfers Up to 32-byte block mode DMA Transmit data transfers 2-Kbyte FIFO for DMA transfers Receive data transfers 4-Kbyte FIFO for DMA transfers Throughput at maximum rate 10 Mbitsisecond Configuration Information Form factor Dual height Power requirements +5 Vdc, 1.5 A +12 Vdc, 0.5 A Power consumption 23.5W Bus loads 3.3 ac 0.
Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
2.3 Real-Time Controllers Real-time controllers interface devices that monitor processes, for example, laboratory equipment or manufacturing equipment. Real-time controllers are typically parallel devices that transmit more than one bit of information simultaneously. 2.3.1 ORQ38 Parallel Interface The DRQ3B is a high-speed parallel interface that provides two independent I6-bit, unidirectional data channels.
Configuration Information 110 port data transceivers Source 16 rnA, sink 64 rnA Performance Throughput rates Burst: 500 kilowords Block: 1.1 megawords Extended block mode: 1.1 megawords Height speed: 1.4 megawords Operating System Support VMS Version 5.0 or later ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
Functional Information 16 data input lines 3 user-definable input status lines 3 user-definable output control lines 8 input control lines 4 output control lines Line characteristics Input data lines 1 TTL unit load each Input control lines 1 TTL unit load each Output data lines 10 TTL unit loads each Output control lines 10 TTL unit loads each Logic levels High = logic 1 Low = logic 0 Ordering Information DRVIW-SF DRVIW field-installed kit Performance Transfer mode Up to 2-byte programmed t
Configuration Information Bus loads 2.0 ac 1.0 dc Module connectors Two 40-pin connectors Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-DRVWA-UG DRVll-WA General Purpose DMA User's Guide 2.3.
Functional Information Remote local Parallel poll Device clear Device trigger Controller Ordering Information IEQll-SF IEQll field-installed kit for IEC connection Performance Transfer mode Programmed 1/0 transfers with interrupt DMA data transfers Data transfer rate Up to 150 Kbytes/second during a DMA block transfer Configuration Information Form factor Quad height Power requirements +5 Vdc, 3.5 A (typical) +12 Vdc, 0.0 A Power consumption 17.5 W Bus loads 2.0 ac 1.
Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-IEUQ1-UG IEUll-AIIEQll-A User's Guide 2.3.4 18Q01 Controller The IBQOl is a DMA controller that interfaces a Q-bus system to R8-485 industrial control and measurement devices.
Performance Bus loads 4.6 ac 1.0 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
Functional Information D/A output Voltage Output voltage range is jumper selectable: ±10 V, ±5 V, or 0 V to +10 V.
Configuration Information Form factor Dual height Power requirements +5 Vdc, 1.8 A (typical) +12 Vdc, 0.0 A Power consumption 9.0W Bus loads 0.9 ac 1.0 dc Operating System Support VMS Version 5.0-2A and later using VAXlab Software Library ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-AVllD-UG Q-Bus DMA Analog System User's Guide 2.3.
Functional Information AID output Resolution 12-bit output data resolution Data notation Binary, offset binary, or 2's complement AID conversions Can be started by a program, a real-time clock, or an external trigger AID results Can be received by a programmed I/O transfer or by servicing an interrupt request Interrupts Can be enabled and automatically set by AID DONE and/or ERROR bits Common mode rejection ratio (gain=1) 80 dB at maximum range Ordering Information ADVll-SF ADVll field-installe
Performance Input bias current ±20 nA at 25°C maximum Input protection Inputs are current-limited and protected to an overvoltage of ±35 V without damage. Common mode rejection ratio 80 dB at a range of ±10 V at 60 Hz AID output Data buffer register 16-bit read-only output register Resolution 12 bits unipolar; 11 bits bipolar plus sign Data notation Binary, offset binary, or 2's complement Sample and hold amplifier Aperture uncertainty Less than 10 nanoseconds Aperture delay Less than 0.5 J.
Operating System Support VMS Version 5.0-2Aand later using VAXlab Software Library ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-AVllO-UG Q-Bus DMA Analog System User's Guide 2.3.
Ordering Information KWVll-SF KWVll field-installed kit UDIP-BAI Universal data interface panel (UDIP) mounting box UDIP-KB Universal data interface panel (UDIP) for KWVll- S UDIP-TA Tabletop enclosure Performance Clock Crystal oscillator 10-MHz base frequency Output ranges 1 MHz, 100 kHz, 10 kHz, 1 kHz, and 100 Hz Oscillator accuracy 0.01% Other sources Line frequency or input at Schmitt Trigger Schmitt-Trigger input signals No.
Performance Duration Approximately 500 nanoseconds Line driver TTL-compatible, open collector circuit with a 470n pull-up resistor to +5 V Maximum source current 5 rnA when output is high (~2.4 V), measuring from source through load to ground Maximum sink current 8 rnA when output is low ($0.
Operating System Support VMS Version 5.0-2A and later using VAXlab Software Library ULTRIX-32 Not supported as of Version 3.0 VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-AXVAA-UG AXVllIKWVll Module User's Guide 2.3.8 AXVll Controller The AXVll-S is an input/output circuit board for analog devices. AXVll-S is functionally equivalent to the AXVll-C.
Functional Information Common mode rejection ratio 80 dB at maximum range D/A converters (DACs) No.
Performance Nonlinearity 0.02% of full-scale value Offset error Adjustable to 0 Offset drift ±30 ppm at maximum Co Gain accuracy Adjustable to full-scale value Gain drift ±30 ppm at maximum Co Settling time 65 J.ls to 0.1% for a p-p output change of 20 V Noise 0.1 % full-scale value Capacitive load capability 0.5 J.lF Configuration Information Power requirements +5 Vdc, 2.0 A +12 Vdc, 0.0 A Power consumption 10.0W Bus loads 1.2 ac 1.0 dc Operating System Support VMS Version 5.
2.3.9 ADQ32 Analog-to-Digital Converter The ADQ32 is an analog-to-digital converter with DMA capability.
Performance Input impedance 10 Mohms, minimum Input bias current 500 nA maximum ON current Input protection Inputs are current-limited and protected to an overvoltage of ±35 V without damage.
Configuration Information Form factor Quad height Power requirements +5 Vdc, 5.0 A (typical) +12 Vdc, 0.0 A Power consumption 25.0W Bus loads 2.5 ac 0.5 dc Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Not supported as of Version 3.0 VAXELN Not supported as of Version 3.2 Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
2.4 MRV11-D Programmable Read-Only Memory Module The MRVll-D memory module contains sixteen 28-pin sockets that accept static random-access memory (RAM) and a variety of user-supplied readonly memories (ROMs). By placing appropriate programmed ROMs onto the module, that data or program will always be available to the CPU. Ordering Information MRVll-D MRVll-D module Configuration Information Form factor Dual height Power requirements +5 Vdc, 2.8 A +12 Vdc, 0.0 A Power consumption 14.0W Bus loads 3.
2.5 Printer Options MicroVAX and VAXserver systems have the following types of printer options: • Line printers • Dot matrix printers • Daisy wheel, letter-quality printers • Ink jet printers • Laser printers 2.5.1 Line Printer Subsystems MicroVAX and VAXserver systems have four line printer options: the LGOl, a text-only printer; the LG02 or the LG31, text and graphics printers; and the LP29, a high-speed impact printer. All require the LPVll-SA printer interface. 2.5.1.
Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.3 and later Self-tests No Related Documentation EK-LPV11-0P LPV11 Printer User's Manual 2.5.1.2 LG01 Text Printer The LGOI is a 600-lines-per-minute impact printer with multiple printing modes.
Performance Multipart forms: carbonless up to 6 parts, carbon or Thickness: 0.06 cm (0.025 in) Power Requirements Line voltage and frequency 90-128 Vac, at 60 Hz 180-256 Vac, at 50 Hz Power consumption 1000 W average Heat dissipation 3000 Btulhour Physical Characteristics Height 97.8 cm (38.5 in) Width 85.1 cm (33.5 in) Depth 57.2 cm (22.5 in) Weight 157.
Related Documentation EK-OLG01-IN LG01600 LPM Text Printer Installation/Operator's Manual EK-OLG01-UG LG01 600 LPM Text Printer User's Guide EK-OLG01-TM LG01 600 LPM Text Printer Technical Manual 2.5.1.3 LG02 Text and Graphics Printer The LG02 is a 600-lines-per-minute impact printer with multiple printing modes and graphics.
Power Requirements Line voltage and frequency 90-128 Vac, at 60 Hz 180-256 Vac, at 50 Hz Power consumption 1000 W average Heat dissipation 3000 Btulhour Physical Characteristics Height 97.8 cm (38.5 in) Width 85.1 cm (33.5 in) Depth 57.2 cm (22.5 in) Weight 157.5 kg (350 Ib) Ordering Information LG02-EA LG02 printer, LPVll-SA, and BC27L-30 cable LG02-JA LG02 printer and BC27L cable for connecting to the second port of the LPVll-SA Operating System Support VMS Version 5.
Performance Near-letter-quality mode Uppercase: up to 147 lines/minute Uppercase and lowercase: up to 105 lines/minute OCR-A and OCR-B 65 lines/minute Print technology Full-character, impact, matrix Character spacing 10/12/13.3/15/16.7 characters/inch, with horizontal and vertical expansion capability Line spacing 6, 8, or 10 lines/inch Paper slew rate 50 cm/second (15 in/second) Character set .
Physical Specifications Height 116.84 cm (46.0 in) Width 73.66 cm (29.0 in) Depth (with paper tray) 103.12 cm (40.6 in) Weight 131 kg (287 lb) Ordering Information LG31-A2 LG31 printer with RS-232 serial interface and BN22D-25 (25-ft cable) Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.2 and later Diagnostic Support MicroVAX Diagnostic Monitor Revision 2.
Ordering Information LP29-QA LP29 printer (120 V) with LPV11 controller, powered paper stacker, and cabinet kit. LP29-Q3 LP29 printer (240 V) with LPV11 controller, powered paper stacker, and cabinet kit.
Power Requirements Line voltage and frequency 100-240 Vac 47-63 Hz Interface (controller) current 1.5 A at 5.0 Vdc Power consumption 455 W, standby; 1000 W, printing Heat dissipation 4013 Btu/hour, printing Physical Specifications Height 124.5 cm (49 in) Width 89.0 cm (35 in) Depth 74.9 cm (29.5 in) Weight 255.0 kg (560 lb) Operating System Support VMS Version 5.0-2A and later ULTRIX-32 Version 3.0 and later VAXELN Version 3.
2.5.2 Dot Matrix Printers Four dot matrix printers are available for the MicroVAX and VAXserver systems: • LA75 Companion Printer • LAIOO Letterwriter • LA120 Printer!I'erminal (DECwriter III) • LA210 Letterprinter 2.5.2.1 LA75 Companion Printer The LA75 Companion Printer is a high-speed, dot matrix printer designed for the office environment.
Performance Character sets Nine built-in character sets: U.S. ASCII, National Replacement (NRC), ISO 8-bit Supplemental, DEC Supplemental, VT100 Special Graphic, DEC Technical, plus IBM Proprinter Line Drawing, Chart Drawing, and Symbol Drawing sets. Buffer capacity 2047-character input buffer Communications Baud rates 110 to 9600 bits/second Character code 7- or 8-bit ASCII with odd, even, mark, space, or no parity Interfaces EIA RS-423 EIA RS-232-C parallel Paper Type Fanfold. Form width: 11.
Physical Specifications Height 12.1 cm (4.8 in) Width 42.7 cm (16.8 in) Depth 34.5 cm (13.6 in) Weight 9.5 kg (21Ib) Ordering Information LA75-CA DEC 423 serial interface printer, U.S., Canada (English, French) 13 other country-specific serial models available LA75P-CA Parallel model, U.S.
2.5.2.2 LA 100 Letterwriter The LAIOO Letterwriter is a wide-carriage, tabletop printer/terminaL Performance Print speed 240 characters/second (draft mode) 30 characters/second (letter-quality mode) 80 characters/second (memo mode), optional Print technology Bidirectional, dot matrix Print matrix Draft-quality: 7 x 9 dots per character cell Near-letter-quality: 33 x 18 dots per character cell Memo-quality: 33 x 9 dots/inch Graphics: 132 x 72 dots/inch Character pitch 16.5, 13.2, 12, 10, 8.25, 6.
Paper Multiple forms Original plus 3 parts Thickness 0.051 cm (0.020 in) maximum Power Requirements Voltage 120 V nominal (87-128 Vac range) Frequency 47 to 63 Hz Power consumption 138 W, printing maximum Physical Specifications Height 17.7 cm (7'in) Width 55.9 cm (22 in) Depth 39.34 cm (15.5 in) Weight 11.
Related Documentation EK-LW100-0P Letterwriter 100 Operator Guide EK-LW100-IN Letterwriter 100 Installation Guide EK-LW100-RM LA100-Series Programmer Reference Manual 2.5.2.3 LA 120 Printer/Terminal (DECwriter III) The LA120 PrinterlTerminal is a dot matrix, pedestal-mounted printer/terminal.
Paper Type Fanfold Dimensions 7.6 cm to 37.8 cm (3.0 in to 14.9 in) wide Multiple forms Up to 6 parts Thickness 0.051 cm (0.020 in) maximum Power Requirements Voltage 120 or 240 Vac, 50 or 60 Hz Power consumption 440 W, printing maximum Physical Specifications Height 85.1 cm (33.5 in) Width 69.9 cm (27.5 in) Depth 61.0 cm (24;0 in) Weight 46.
Related Documentation EK-LA120-RG LA120 Operator's Reference Card EK-LA120--TM LA120 Technical Manual EK-LA120-UG LA120 User Guide 2.5.2.4 LA210 Letterprinter The LA210 Letterprinter is a multimode, dot matrix, desktop printer.
Communications Interfaces EIA RS-232-C Optional parallel interface Paper Type Single sheet, pinfeed, or continuous forms Dimensions 8.9 cm to 37.8 cm (3.5 in to 14.9 in) wide Multiple forms Original plus 3 parts (bottom feed only) Thickness 0.038 cm (0.015 in) maximum Power Requirements Voltage 120 V nominal (90-128 Vac range) 240 V nominal (180-256 Vac range) Frequency 47 to 63 Hz Power consumption 154 W, printing maximum Physical Specifications Height 12.7 cm (5 in) without tractor 22.
Ordering Information LA210-AA United States (English) LA210-AE UKlIreland (English) Other country-specific models are available Operating System Support VMS Dependent on serial interface port ULTRIX-32 Dependent on serial interface port VAXELN Dependent on serial interface port Diagnostic Support MicroVAX Diagnostic Monitor Dependent on serial interface port Self-tests Yes Related Documentation EK-LA210-UG LA210 Letterprinter User Guide EK-LA210-IN Installing the LA210 Letterprinter EK-LA
2.5.3 Letter-Quality Printers The LQP series of printers provides letter-quality printing for MicroVAX and VAXserver systems. 2.5.3.1 LQP02 Printer The LQP02 letter-quality printer is a full-size, 96-petal daisywheel printer.
Physical Specifications Height 17.8 cm (7 in) Width 63.5 cm (25 in) Depth 40.
Performance Print speed 25 characters/second (Shannon text at 10 characters/inch) 34 characters/inch (triple-A text at 12 characters/ inch) Print technology Bidirectional, full-character, impact Print density Full-character, even density Paper Cutsheet: U.S.: 21.6 x 27.9 cm (8.5 x 11 in); A4: 21.1 x 29.7 cm (8.3 x 11.7 in); both in vertical and horizontal orientation; 16-24 lb bond Type. Characteristics Character sets ASCII, English/U.K.
Communications Transmission rate Full-duplex, from 110 to 9600 baud Buffer capacity 256 characters Buffer control XONIXOFF Power Requirements VoltagelFrequency 90-132 V, 57-63 Hz; 180-264 V, 47-53 Hz Line current 14 A, maximum starting current; 1 A nominal operating current Power consumption Less than 100 W, average RMS Heat dissipation 410 Btulhour, nominal operation Physical Specifications Height 19.7 cm (7.75 in) Width 52.7 cm (20.75 in) Depth 38.7 cm (15.25 in) Weight 22.
Diagnostic Support MicroVAX Diagnostic Monitor Dependent on serial interface port Self-tests Yes Related Documentation EK-LQP03-UG Installing and Using the LQP03 Printer EK-LQP03-RM LQP03 Printer Programmer Reference Manual EK-LQP03-TM LQP03 Printer Technical Manual Option Specifications 2-91
2.5.4 Ink Jet Printers Ink jet printers provide high-quality color graphics with near-letter-quality text. 2.5.4.1 LJ250/LJ252 Companion Color Printers LJ250ILJ252 Companion Color Printers are disposable cartridge, thermal ink jet printers, available with either serial or parallel interface.
Performance Character code Bit serial, character asynchronous, consisting of a start bit (space), 7 or 8 data bits (1 = mark, 0 = space), an optional parity bit, and a stop bit (mark) Communications baud rates 4800 or 9600 Buffer control XONIXOFF or DTR Buffer capacity 2 Kbytes of input buffer space Power Requirements Line voltage and frequency 100, 120, 220, 240 Vac 48-66 Hz Physical Specifications Height 9.2 cm (3.65 in) Width 44.4 cm (17.50 in) Depth 31.1 cm (12.25 in) Weight 4.
Diagnostic Support MicroVAX Diagnostic Monitor Dependent on serial interface port Self-tests Yes Related Documentation EK-LJ250-DK LJ2501LJ252 Companion Color Printer Documentation Kit Option Specifications 2-95
2.5.5 Laser Printers Three models of the LN03 laser printer offer laser imaging and xerographic printing in a desktop unit. They are described on the following pages.
Performance ReGIS (LN03R) LN03: no on-board RAM; accepts two RAM cartridges RAM LN03 PLUS: 1 Mbyte on-board RAM; accepts two RAM cartridges LN03R: 2 Mbytes on-board RAM; accepts two RAM cartridges ROM LN03: no on-board ROM; accepts two precoded ROM font cartridges LN03 PLUS: no on-board ROM; accepts two precoded ROM font cartridges LN03R: 1 Mbyte of on-board ROM for POSTSCRIPT interpreter; accepts two precoded ROM font cartridges Communications Interface EIA RS-232-C Baud rates 1200, 2400, 3600, 4800
Ordering Information LN03-AA U.S. model of LN03 LN03S-AA U.S. model of LN03 PLUS LN03R-AA U.S.
Chapter 3 System Expansion Expanding a system involves three activities: • Determining whether the system can accommodate a particular set of supported options • Configuring the options appropriately • Installing the options in the correct positions within the system This chapter describes only how to determine what options you can add to your system. You do this by filling in a worksheet with the options currently in your system and those you want to add.
Table 3-1: Power Requirements Option Module Current (Amps) Current (Amps) Power (Watts) +12V +5V AAV11-SA AlO09-PA 1.8 0.0 9.0 ADQ32-SA A030-PA 5.0 0.0 25.0 ADV11-SA AlO08-PA 3.2 0.0 16.0 AXV11-SA A026-PA 2.0 0.0 10.0 CXAI6-AAlAF M3118-YA 1.4 0.14 8.7 CXBI6-AAlAF M3118-YB 1.4 0.14 8.7 CXF16 M3123 2.0 0.0 10.0 CXF32 M3123 2.0 0.0 10.0 CXY08-AAlAF M3119-YA 1.3 0.14 8.2 DELQA-SA/SF M7516-PA 1.5 0.5 23.5 DESQA-SA/SF M3127 2.4 0.22 14.
Table 3-1 (Cont.): Option Power Requirements Module Current (Amps) Current (Amps) Power (Watts) +12V +5V RV20 2 to 21 0.2 to 3.9 175 TK50S-AA 1.35 2.4 35.6 TK70S-AA 1.3 2.4 35.3 TQK50-SA M7546 2.9 0.0 14.5 TQK70-SA M7559 3.0 0.0 15.0 TSV05-SB M7206-PA 6.5 0.0 32.5 Figure 3-1 shows the worksheet for the BA213 enclosure. worksheet as follows: Use the 1.
Figure 3-1 : Configuration Worksheet PRIMARY POWER SUPPLY SLOT MODULE Current (Amps) +12 Vdc +5 Vdc Power (Watts) 1 M7624 6.0 0.24 32.88 2 M7621-A 2.7 0.0 13.5 1.3 2.4 35.3 33.0 A 7.6A 230.0 W 3 4 5 6 MASS STORAGE: TK70 FIXED DISK 0 Total these columns: Must not exceed: SECONDARY POWER SUPPLY SLOT MODULE Current (Amps) +5 Vdc +12 Vdc Power (Watts) 7 8 9 10 11 12 MASS STORAGE: FIXED DISK 1 FIXED DISK2 Total these columns: Must not exceed: 33.0 A 7.6A 230.
Index A AAVll-S specifications, 2-51 ADQ32 specifications, 2-62 ADVll-S specifications, 2-53 Asynchronous serial controllers, 2-17 AXVll-C specifications, 2-59 B Base system components, 1-1 specifications, 1-1 Battery backup unit (BBU), 1-10 Baud rates changing, 1-7 supported, 1-9 Baud rate switch location, 1-7 BBU See Battery backup unit BOOT command, 1-5 Break EnablelDisable switch on the CPU panel, 1-7 c Communications options, 2-17 CXA16 asynchronous controller, 2-17 CXB16 asynchronous controller, 2-2
DFAOI specifications, 2-25 DHUll mode, 2-17 DHVll mode, 2-17 Digital Small Storage Interconnect See DSSI, 1-1 Disk drives, 2-2 RF30, 2-2 DMVll specifications, 2-35 Dot matrix options LAI00 Letterwriter, 2-80 LA120 printer/terminal (DECwriter III), 2-82 LA210 Letterprinter, 2-84 LA75 Companion printer, 2-77 DPVll specifications, 2-37 DRQ3B parallel interface specification, 2-45 DRVIW specifications, 2-46 DSRVB DEC server 200 specifications, 2-30 DSSI architecture, 1-2 bus characteristics, 1-2 DSVll synchrono
Line printer options (cont'd.