Specifications

6–30
Replacement Procedures and Parts
Platen Open Switch (FD–15791–01)
1. Unplug the printer power cord from the AC receptacle to insure that
there are no hazardous voltages present while servicing this equipment. It
is also recommended that an anti–static wrist strap (29–26246–01) be
worn, especially while servicing logic components.
2. Remove the platen belt cover by depressing down to release the top tab,
then tip the cover out while pulling upward.
3. Remove the lower paper guide (Figure 6–7, page 6–40, item #16), four
(4) 1/4” screws. This will allow access to the platen open switch
nutplate.
4. Remove the two connectors from the switch, noting their position for
correct re–installation.
5. Remove the two (2) allen screws while holding the mating nutplate. Take
care so as not to drop the two spacers behind the switch.
6. For re–installation of the new platen open switch, reverse the removal
steps.