Specifications

6–29
Replacement Procedures and Parts
Platen Open Motor and Belt (29–29282–01) (29–30899–01)
1. Unplug the printer power cord from the AC receptacle to insure that
there are no hazardous voltages present while servicing this equipment. It
is also recommended that an anti–static wrist strap (29–26246–01) be
worn, especially while servicing logic components.
2. Remove the platen belt cover by depressing down to release the top tab,
then tip the cover out while pulling upward.
3. Remove the lower paper guide (Figure 6–7, page 6–40, item #16), four
(4) 1/4” screws. This will allow access to the platen open motor.
4. If replacing the platen belt, adjust the Platen Open Belt (page 5–24), and
return the printer to an operational state.
5. If replacing the platen open motor, remove both the top and bottom
mounting screws, and the power connector (PLM). Replace the motor,
adjust the Platen Open Belt (page 5–24), and return the printer to an
operational state.