Specifications

5–12
Adjustments
Magnetic Pickup Gap (Figure 5–5)
NOTE: Unless otherwise directed, do the MPU phasing adjustment (page
5–14) immediately after this procedure.
1. Loosen the two captive screws and remove the cam cover (1).
2. Loosen the clamping screw (2) enough to allow the MPU (3) to be
rotated.
3. Set the gap between the MPU and the flywheel (4) using a flat feeler
gauge (5):
a. If a blue mark is on the flywheel, use a 0.002 inch feeler gauge and
set the gap in line with the blue mark.
b. If the flywheel does not have a blue mark, use a 0.008 inch feeler
gauge.
4. Tighten the clamping screw (2). Verify that the MPU does not rotate.
5. Adjust the MPU phasing (page 5–14).