User`s manual

7–130 Digital Emulation
Default Values and States
The printer stores a set of typical operating states and conditions in ROM.
The first time you power up the printer, the factory settings in Table 7–22 are
automatically invoked.
Table 7–22. Factory Settings
Selectable Parameter Control Function Factory Set Condition
Printing Status ––––– Off–line
Horizontal Pitch DECSHORP 10 characters per inch
Vertical Pitch DECVERP 6 lines per inch
Font SGR Data Processing
Forms Length DECSLPP 66 lines (11 inches)
Active Position ––––– Column 1, line 1
Top Margin ––––– Line 1
Bottom Margin ––––– Line 66
Left Margin ––––– Column 1
Right Margin ––––– Column 136
Underlining SGR Disabled
Bolding SGR Disabled
Italics SGR Disabled
Double Underline SGR Disabled
Overline SGR Disabled
Expansion GSM No character expansion
GL Character Set ––––– US ASCII
GR Character Set ––––– Digital Supplemental
G0 Character Set ––––– US ASCII
G1 Character Set ––––– VT100 Graphic Character Set
G2 Character Set ––––– Digital Supplemental
G3 Character Set ––––– US ASCII
Autowrap DECAWM Disabled
Line Feed/New Line Mode LNM Reset
Horizontal Tabs ––––– Stop at every 8 columns (9, 17...137)
Unsolicited Reports DSR Disabled
Super/Subscripts ––––– Disabled
Carriage Return/NLM DECCRNLM Reset
Vertical Tabs ––––– Stop at every line (1–66)