User`s manual
7–57Digital Emulation
Logos
A logo is a graphic image stored in the printer. Once a logo is downloaded, it
can be printed repeatedly by referring to its identifying number. Up to 16
logos can reside in the printer, with a maximum size of 65,000 bytes per
logo. The following subsections explain various ways in which to utilize the
logo feature.
Loading Logos Sequence (DECLLG)
ASCII Code DCS P1 ; P2 & t RECORD ST
Hex Code 90 P1 3B P2 26 74 RECORD
Dec Code 144 P1 59 P2 38 116 RECORD
Purpose Loads logos into printer memory.
Discussion Pn parameters select the format and the logos to be deleted before
loading this form.
• P1 specifies the logo file indicator that chooses the logo file format used
in the command string. The indicator number must be 0 and the file
must be in the LG02 logo file format. If not, the entire load logo set is
ignored. Default: P1 = 0.
• P2 lists the logos to be deleted.
P2 Function
Delete all logos
0
Delete any logo with the same Logo ID as this one
Others
Logos can be loaded at any time except during another download operation
and during a form printing operation. When loaded, they are available for
selection until:
• New logos are loaded with P2 = 3 (replace all logos).
• A logo with the same number is loaded (the new logo, though the same
number, will replace the old).
• System power is turned off (all loaded logos are lost).