Specifications

4–16 Adjustment Procedures
Platen Angle Adjustment (Figure 4–8 )
1. Prepare the printer for maintenance (page 4–2).
2. Remove the shuttle cover (page 5–24).
3. Close the forms thickness lever (1) all the way.
4. Install the platen position gauge (P/N 996083) (2) and check the angle
of the platen (3).
c. If the angle is correct, no adjustment is necessary. Go to step 8.
d. If the angle is incorrect, loosen the clamp screw (4) and set screw
(5).
5. Apply primer and loctite to the mating surfaces of the forms thickness
lever (1) and platen shaft.
6. Position the platen (3) at the correct angle.
7. Slide the platen (3) to the right and the forms thickness lever (1) to the
left to remove end play. Ensure that the forms thickness lever is fully
closed. Tighten the clamp screw (4), then tighten the setscrew (5).
8. Remove the platen position gauge (P/N 996083) (2).
9. Install the shuttle cover (page 5–24).