User guide

17
Initial State Values for the LA600
MultiPrinter
This chapter lists the values used by the LA600 MultiPrinter printer for:
A power-up reset or a recall of factory default values
The Select Conformance Level (DECSCL) command
The Soft Terminal Reset (DECSTR) or Reset to Initial State (RIS)
commands
17.1 Initial States
Table 17–1 lists the initial state values used by the LA600 MultiPrinter. The
printer always powers up in Ready mode if no error is detected.
Table 17–1 Initial State Values for LA600
Variable or
Control Function DECSCL Power-Up
DECSTR
RIS
Recall
Factory
Defaults
(Setup)
Active Macro Unchanged NVM
1
Unchanged Macro 1
Protocol Unchanged NVM DEC PPL2
8
DEC PPL2
Origin (DECHPWA) Unchanged 0 Unchanged 0
Vertical pitch 6 lpi NVM NVM 6 lpi
Proportional mode Reset Reset Reset Reset
Horizontal pitch 10 cpi NVM NVM 10 cpi
1
NVM indicates that the initial state value is stored in the nonvolatile memory of the LA600.
8
RIS does not affect protocol (different behavior than DECSTR).
(continued on next page)
Initial State Values for the LA600 MultiPrinter 17–1