User guide

Initial State Values for the LA310 MultiPrinter
10.1 Initial States
Table 10–1 (Cont.) Initial State Values for LA310
Variable or
Control Function DECSCL Power-Up
DECSTR
RIS
Recall
Factory
Defaults
(Setup)
Paper Position at
power-up
Unchanged Line 1 Unchanged Line 1
CRM Unchanged Disabled
5
Unchanged Disabled
C1 Receive 8-Bit 8-Bit Unchanged 8-Bit
Device ID (DA) Unchanged NVM Unchanged DEC PPL2
Form Length 11" NVM NVM 11"
Margins Paper edge Paper edge Paper edge Paper edge
Automatic Test Mode Unchanged Disabled Unchanged Disabled
5
When CRM is enabled by software, it can only be disabled by software or by powering down the
printer. When CRM is enabled, the protocol switching commands that cause a power-up reset are
not performed. The LA310 can also enable DUMP printing from the printer front panel. This mode
cannot be disabled by software.
Initial State Values for the LA310 MultiPrinter 10–3