Service manual
LA600 Field Service Manual
Digital Equipment Corporation Page 3-29
LA600 Field Service Manual
Part: Protection Shield DEC P/N: FD-W041W-01
Part No: 5112 292 38390
REMOVAL
Disconnect mains cable
Open top cover
Remove Ink Ribbon
Remove Platen
⇒ Dismount protection shield (B) by loosening the two screws (A).
This can easily be done by inserting of a torx screwdriver of at
minimum 110 mm length through the holes (C) in the bottom
plate and the platen channel
REASSEMBLING
Execute the REMOVAL procedure in reverse sequence
Page 3-30 Digital Equipment Corporation