LA600 Field Service Manual
Digital Equipment Corporation Page 3-21
LA600 Field Service Manual
Part: Kit Lubrication Felt DEC P/N: 29-31804-01. A01
Part No: 5112 270 04541
REMOVAL
Disconnect mains cable
Remove all encasing parts (see Part: Housing)
Remove Encoder Strip Assy (see Part: Encoder Strip Assy)
Remove operator panel, but leave the interface cable connected
(see Part: Operator Panel)
⇒ a) Remove the two springs (C)
b) Remove the upper guide rail (D)
⇒ Exchange the lubrication felt (E). Insert the new felt with
flatten ear towards the operator panel
REASSEMBLING
Execute the REMOVAL procedure in reverse sequence
Caution:
Pay attention that the encoder strip Assy is mounted in a
correct position (Detail Z) and observe that the strip is
slipping under the first two steel noses seen from the front
side of the printer
Page 3-22 Digital Equipment Corporation