Part: Cable Print Head Assy DEC P/N: FD-W02Y2-01
Part No: 5112 292 38800
REMOVAL
Disconnect mains cable
Remove all encasing parts (see Part: Housing)
⇒ a) Disconnect print head cable from the print head
b) Remove the noise reduction foam (A) from the cable channel
c) Clip the plastic support (B) from the print head carriage, by
first releasing clamps (C)
d) Disconnect the wire-to-wire connection (D) of the H-Encoder
Assy
e) Disconnect the colour option, if installed, incl.connector
f) Disconnect cable (E) from the interface connection board
g) Disconnect the print head cable from DEV-40 LA600 Assy
h) Remove the two plastic clips (F)
i) Remove the print head cable
REASSEMBLING
Execute the REMOVAL procedure in reverse sequence