Service manual

1
2
Detail A
DEC Field Service Instruction
7-36 7-37
Part: Stepper Motor 7.5 DEG Part No.: 5112 292 4106x
(Platen gap control) DEC P/N.: FD-W0394-01
REMOVAL
" Disconnect mains cable
" Remove all encasing parts (see Part: Housing)
" Remove DEV-40A (see Part: DEV-40)
Y M Disconnect the four pin motor cables from the motors plug
Y M Remove the two screws (1) fixation of the stepper motor
Warning: Do not loosen the screw (2). This is a factory adjustment;
field adjustment is impossible
Y M Remove the stepper motor
REASSEMBLING
" Execute the REMOVAL procedure in reverse sequence
Note: Make sure that the cable installation is correct (Detail A)
5112 991 10583