Service manual

2
1
3
3
4
DEC Field Service Instruction 5112 991 10526
7-32 7-33
Part: Protection Shield Part No.:5112 292 3839x
DEC P/N.:FD-W041W-01
REMOVAL
" Disconnect mains cable
" Open top cover
" Remove Ink Ribbon
" Remove Platen (4)
Y M Disconnect protection shield (1) by loosening the two screws (2).
This can easily be done by inserting of a torx screwdriver of at
minimum 110 mm length through the holes (3) in the bottom plate
and the platen channel
REASSEMBLING
" Execute the REMOVAL procedure in reverse sequence