Service manual

4
5
3
2
DEC Field Service Instruction 5112 991 12393
7-24 7-25
Part: Kit Lubrication Felt Part No.:5112 212 5589x
DEC P/N.: 29-31804-01
REMOVAL
" Disconnect mains cable
" Remove all encasing parts (see Part: Housing)
" Remove Encoder Strip (1) (see Part: Encoder Strip)
" Remove operator panel, but leave the interface cable connected (see Part:
Operator Panel)
Y M Remove srew (2) on both sides of the upper guide rail (3)
Y M Remove the upper guide rail (3)
Y M Exchange the lubrication felt (4). Insert the new felt with flatten
ear (5) towards the operator panel
REASSEMBLING
" Execute the REMOVAL procedure in reverse sequence