User`s guide
StorageWorks RAID Array 200 Subsystem Family
Step
Action
Result
6
Repeat this procedure for up to eight
logical RAID drives, or until all the
capacity of the selected drive group is used.
Each new logical RAID drive is
added to the table on the lower-left
of the screen.
7
Choose a caching policy. The default
policy is Write-Thru (Through).
To change the cache policy, select the
Toggle Write Policy option on the menu.
NOTE: Digital strongly recommends a
Write-Through caching policy to eliminate
the chance of data loss due to a power
failure. See the Terminology section in the
About this Guide portion of this manual.
The cursor moves to the right-hand
column of the list of logical RAID
drives and highlights the Write-Thru
of the first logical RAID drive.
8
Press the Enter key to toggle the caching
policy to the alternative: Write-Back.
Use the arrow keys to move to another
logical RAID drive.
9
When you are finished with the cache
policy, press the ESC key once.
You return to the Logical Drive
Definition menu.
10
Press the ESC key again.
You return to the New Configuration
menu.
11
Press the ESC key again.
The system displays a confirmation
window.
12
Select Yes in the confirmation box.
The configuration is saved to the
flash EEPROM/NVRAM. The
system returns you to the main
menu. You can now initialize the
logical RAID drives.
5-24