User`s guide
StorageWorks RAID Array 200 Subsystem Family
Installing Cables and Storage Pedestals
This chapter describes the cabling and installation procedure for the storage pedestals.
If you are installing a system with embedded disk drives, refer to that system's
documentation for cabling instructions.
______________________ NOTE____________________________
If the SCSI port is set to the default values of synchronous and 10 MB/s
(FAST), the total cable length cannot exceed three meters (two meters for
the cable and one meter for the storage pedestal).
To install the storage pedestals and make the cable connections, you follow these
steps.
1. Unpack the Y-cable, the BN21H-02 2-meter cable, and the storage pedestals.
Place the storage pedestals where they are to be used and label them.
______________________ NOTE____________________________
Depending on your configuration, you can install one, two, or three
storage pedestals on the RAID controller. Label the first pedestal as
Pedestal 0. Any other pedestals are labeled Pedestal 1 and Pedestal 2,
respectively. Pedestal 0 connects to Channel 0, Pedestal 1 connects to
Channel 1, and Pedestal 2 connects to Channel 2.
2. Unlock and open the front and rear bezel doors. See Figure 4-3.
4-4