User`s guide
Chapter 2
14. Ensure that the controller board is configured with these recommended
option defaults.
Option
Default Setting
Disk spin-up options
2 disks started every 6 seconds - Default
Tag-queuing
Enable tag-queuing - Default
Transfer-rate
Synchronous, 10 MB/s (FAST) - Default
BIOS
For AXP systems, disable this option.
For Intel systems, enable this option. See the
note below.
With regard to the Interrupt (level), if your system already has more than one
board installed, the ECU should assign a different interrupt level to the new
board you are installing. Before you select the edge/interrupt option, consult
your system documentation to ensure that your system supports edge
interrupts.
You can configure the RAID controller interrupt levels to these settings:
11 Level 11 Edge
12 Level 12 Edge
15 Level 15 Edge (For NetWare only, do not use Level 15.)
_______________ NOTE for Intel Systems _____________________
If your boot device is an EISA adapter, verify that the BIOS address of the
SWXCR controller is set to a value greater than that of the adapter from
which you boot your computer.
If you are installing a second SWXCR controller, you must disable the
BIOS on the second controller.
2-11