User`s guide

Chapter 6
Error/Problem
Possible Cause(s)
Action(s) To Take
Warning: x system
drive is dead
Drive failed in a nonredundant
RAID Logical Drive (0 or
JBOD).
More than one drive failed in a
redundant RAID level logical
RAID drive (1, 0 + 1, 5).
Check all power, cabling, and
hardware for proper operation.
Data integrity can not be
maintained, you must correct the
situation and restore data from a
backup source.
1. Run the utilities.
2. Identify failed drive or drives.
3. Replace failed drive or drives.
4. Reinitialize the RAID logical
drive.
5. Restore data from backup.
Warning: the
following SCSI
devices are dead
Chn x, Tgt y
Drive failed.
Run the utilities to identify failed
drive. Replace drive using the
Replacing a Drive SBB section of
this chapter.
Configuration Error
on SWXCR-E in Slot
xx!!
An error has occurred in
configuring the controller into the
system.
Run the system EISA
Configuration Utility (ECU) to
correct problem.
Continued on the next page.
6-23