User`s guide

StorageWorks RAID Array 200 Subsystem Family
______________________ NOTE____________________________
To minimize the chance of data loss due to a second drive failure, upon
detection of a drive failure, replace the drive as soon as possible.
To manually rebuild data of a failed physical drive (if you have not defined a hot
spare drive), follow these steps.
Step
Action
Result
1
Remove the failed drive from the RAID
subsystem and replace it with a new drive.
2
Go to the main menu and select the Rebuild
option.
The system displays a screen
with the drive matrix, showing
the drives and their status.
The new drive is recognized by
the system and spun up. The
status of the new drive remains
FLD (failed) until the rebuild
begins.
3
Select the drive to be rebuilt. The drive you
select must have a FLD (failed) status.
The rebuild status bar gradually
fills as the process completes.
4
When the bar displays 100%, press any key to
continue.
The system returns you to the
main menu.
5-46