User`s guide
StorageWorks RAID Array 200 Controller Installation and Standalone Configuration Utility
5–16 EK–SWRA2–IG. C01
Figure 5–13 Routing the SCSI Cable — Method 2
5.2.2.3 Cable Installation — Method 3
1. Open the front and rear bezel doors of each pedestal and remove both bezels
from the pedestal by pressing down on the locking tabs at the bottom of each
bezel.
2. Remove a knockout panel on the front bezel that is closest to the host com-
puter (see Figure 5–12).
3. Connect the cable to connector JA1 (upper-left connector when viewed from
the front) on the internal side of the backplane (see Figure 5–14)
4. Replace the bezel ensuring the locking tabs snap into place at the bottom of
the bezel.
5. Insert the other end of the SCSI cable into the appropriate RAID controller
connector at the back of the host system.