User`s guide

Chapter 5. 3-Channel RAID Controller Installation
EK–SWRA2-IG. C01 5–15
5.2.2.2 Cable Installation - Method 2
1. Open the front and rear bezel doors of each pedestal and remove both bezels
from the pedestal by pressing down on the locking tabs at the bottom of each
bezel.
2. Remove a knockout panel on the rear bezel that is closest to the host com-
puter and route the SCSI cable through the cutout. (See Figure 5–12).
3. Loop the cable below the divider plate and connect the cable to connector
JA1 (upper-left connector when viewed from the front) on the internal side
of the backplane (see Figure 5–13).
4. Replace the bezel, ensuring the locking tabs snap into place at the bottom of
the bezel.
5. Insert the other end of the SCSI cable into the appropriate connector for the
RAID controller at the back of the host system.
Figure 5–12 Removing a Knockout Panel