User`s guide

Chapter 5. 3-Channel RAID Controller Installation
EK–SWRA2-IG. C01 5–7
5.2 Cabling
Cabling from the RAID controller board can be to an internally mounted storage
array or to the Expansion Storage Pedestal. If the board is connected to an inter-
nal array, refer to the documentation that came with the array to see that it is
properly configured. When using the Expansion Storage Pedestal, the proper in-
stallation of the Shelf_OK signal jumpers must be verified. The instructions for
this verification are covered in the following paragraphs. The installation shown
is an example, refer to the appropriate StorageWorks Storage Pedestal User’s
Guide for general setup and cabling information.
NOTE
Depending on your configuration, you can install
one, two, or three storage pedestals on the RAID
controller. Label the first pedestal as Pedestal 0.
The other pedestals are labeled Pedestal 1 and
Pedestal 2, respectively. Pedestal 0 connects to
Channel 0, Pedestal 1 connects to Channel 1, and
Pedestal 2 connects to Channel 2.