User`s guide

Chapter 4. 1-Channel RAID Controller Installation
EK–SWRA2-IG. C01 4–7
The Expansion Storage Pedestal has an internal wiring length equivalent to 1
meter of cabling, therefore, the external cabling cannot exceed 2 meters. There are
three methods of routing the cable within the pedestal. Read each cable
installation procedure and then choose the best one for your location, depending
upon the length of the cable used and the appearance desired.
4.2.2.1 Cable Installation - Method 1
1. Open the front and rear bezel doors and remove both bezels from the pedestal
by pressing down on the locking tabs at the bottom of each bezel.
2. Thread one end of the SCSI cable under the rear handle of the pedestal base,
and through the opening at the top of the pedestal to the front of the unit (see
Figure 4-7).
3. Remove the filler panel or SBB from topmost slot of the pedestal.
4. Loop the cable down below the divider plate and connect the cable to
connector JA1 (upper-left connector when viewed from the front) on the
backplane (see Figure 4-7).
5. Replace the filler panel or SBB removed in step 2. Replace the front and rear
bezels and ensure that the locking tabs snap into place at the bottom of each
bezel.
6. Insert the other end of the SCSI cable into the appropriate RAID controller
connector at the back of the host system.