User`s guide

StorageWorks RAID Array 200 Controller Installation and Standalone Configuration Utility
8–18 EK–SWRA2–IG. C01
Figure 8–5 Error Messages (continued)
Error/Problem Probable Cause Action(s) to Take
Warning: x system
drive is degraded
Drive failed in a re-
dundant RAID Logi-
cal Drive.
Run the utilities to check the drive
status.
Replace the appropriate failed
drive.
Warning: x system
drive is dead
Drive failed in a non-
redundant RAID
Logical Drive (0 or
JBOD).
More than one drive
failed in a redundant
RAID level logical
RAID drive (1, 0 + 1,
5).
Check all power, cabling, and
hardware for proper operation.
Data integrity can not be main-
tained, you must correct the situa-
tion and restore data from a backup
source.
Run the utilities.
Identify failed drive or drives.
Replace failed drive or drives.
Reinitialize the RAID logical drive.
Restore data from backup.
Warning: the follow-
ing SCSI devices
are dead Chn x, Tgt
y
Drive failed. Run the utilities to identify failed
drive. Replace drive using the
Re-
placing a Drive SBB
section of this
chapter.
Configuration Error
on SWXCR-E in
Slot xx!!
An error has oc-
curred in configuring
the controller into the
system.
Run the system EISA Configuration
Utility (ECU) to correct problem.