User`s guide
StorageWorks RAID Array 200 Controller Installation and Standalone Configuration Utility
8–14 EK–SWRA2–IG. C01
Table 8–5 Error Messages (continued)
BIOS Messages
Error/Problem Probable Cause Action(s) to Take
Cannot find
SWXCR in any slot:
no drives installed
• RAID controller not
properly seated in
EISA slot.
• RAID BIOS is not
enabled on the
board in the lower
EISA slot.
• BIOS on more than
one RAID control-
ler is enabled.
• Defective EISA
slot.
• Controller failure.
• Remove and reseat the controller.
• Rerun ECU and correct problem.
• Rerun ECU and disable appro-
priate BIOS.
• Try another EISA slot in your
system.
• Replace the controller.
SWXCR not re-
sponding - no
drives installed
• Incorrect firmware
on controller.
• Defective control-
ler.
• Reload correct firmware on con-
troller.
• Replace with new controller.