User`s guide

StorageWorks RAID Array 200 Controller Installation and Standalone Configuration Utility
8–14 EK–SWRA2–IG. C01
Table 8–5 Error Messages (continued)
BIOS Messages
Error/Problem Probable Cause Action(s) to Take
Cannot find
SWXCR in any slot:
no drives installed
RAID controller not
properly seated in
EISA slot.
RAID BIOS is not
enabled on the
board in the lower
EISA slot.
BIOS on more than
one RAID control-
ler is enabled.
Defective EISA
slot.
Controller failure.
Remove and reseat the controller.
Rerun ECU and correct problem.
Rerun ECU and disable appro-
priate BIOS.
Try another EISA slot in your
system.
Replace the controller.
SWXCR not re-
sponding - no
drives installed
Incorrect firmware
on controller.
Defective control-
ler.
Reload correct firmware on con-
troller.
Replace with new controller.