Table 8–4 Troubleshooting Techniques (continued)
Symptom Possible Cause(s) Action(s) to Take
Automatic Rebuild
Does Not Start
Automatic rebuild
feature is not sup-
ported for one of
the following rea-
sons:
A StorageWorks
pedestal is not be-
ing used.
Fault Management
is disabled.
Rebuild in progress
on another logical
RAID drive
If you are using the Storage-
Works pedestal perform the fol-
lowing:
Verify that Fault Management is
enabled. Refer to the
Setting
Controller Parameters
and
Fault
Management and Battery Backup
Options
in Chapter 6.
Remove the failed drive. Wait a
minimum of 20 seconds and then
insert the replacement drive. Wait
approximately 1 minute for the
rebuild to begin.
Wait for completion of the rebuild
in progress. If a rebuild does not
start automatically after you in-
serted a new drive, then start a
manual rebuild.
If rebuild continuously fails to
automatically start, contact your
service representative.
Automatic Rebuild
Starts and then
Fails
You used a drive
of smaller capacity
to replace a failed
drive.
The new drive may
be defective.
Another drive in
the drive group
may have errors.
Check to be sure that the re-
placement size is the proper
type/capacity for the drive group.
If the replacement drive consis-
tently fails during the rebuild, it
may be defective. Try another
drive.
Check drive error logs. Invoke the
utilities and select the Bad Block
option from the Tools menu to
check for bad blocks on the drive.