User`s guide
StorageWorks RAID Array 200 Controller Installation and Standalone Configuration Utility
8–10 EK–SWRA2–IG. C01
Table 8–4 Troubleshooting Techniques (continued)
Symptom Possible Cause(s) Action(s) to Take
Automatic Rebuild
Does Not Start
• Automatic rebuild
feature is not sup-
ported for one of
the following rea-
sons:
• A StorageWorks
pedestal is not be-
ing used.
• Fault Management
is disabled.
• Rebuild in progress
on another logical
RAID drive
• If you are using the Storage-
Works pedestal perform the fol-
lowing:
• Verify that Fault Management is
enabled. Refer to the
Setting
Controller Parameters
and
Fault
Management and Battery Backup
Options
in Chapter 6.
• Remove the failed drive. Wait a
minimum of 20 seconds and then
insert the replacement drive. Wait
approximately 1 minute for the
rebuild to begin.
• Wait for completion of the rebuild
in progress. If a rebuild does not
start automatically after you in-
serted a new drive, then start a
manual rebuild.
• If rebuild continuously fails to
automatically start, contact your
service representative.
Automatic Rebuild
Starts and then
Fails
• You used a drive
of smaller capacity
to replace a failed
drive.
• The new drive may
be defective.
• Another drive in
the drive group
may have errors.
• Check to be sure that the re-
placement size is the proper
type/capacity for the drive group.
• If the replacement drive consis-
tently fails during the rebuild, it
may be defective. Try another
drive.
• Check drive error logs. Invoke the
utilities and select the Bad Block
option from the Tools menu to
check for bad blocks on the drive.