7–60 EK–SWRA2–IG. C01
7.5.6 Drive Error Counts
The standalone configuration utility keeps a count of drive errors that occur
while the utility is running. You can view the number of drive error occurrences
and the general type of error (hard, soft, and others) in a table. View the table to
see the number and nature of errors being produced by a drive. Use this
information to determine the reliability of a drive and whether to replace it.
The Error Counts Table displays a maximum of 127 errors.
To view the error count for a drive, follow these steps.
1. Use the up and down arrow keys to highlight the Tools option on the main
menu and press the Enter key to select it. The Tools menu appears.
2. Use the up and down arrow keys to highlight the Error Count option on the
Tools menu and press the Enter key to select it. The cursor appears in the
drive matrix.
3. Use the arrow keys to select the drive for which you want to view errors, and
press the Enter key. The utility displays a screen similar to Figure 7–35.
4. After viewing the errors screen, press any key to return to the Tools menu.
5. Press the Esc key and the drive no longer appears highlighted.
6. Press the Esc key again to return to the main menu.