User`s guide

Chapter 7. Maintaining the Array with the Standalone Configuration Utility
EK–SWRA2–IG. C01 755
To manually rebuild a drive, follow these steps:
1. Replace the failed drive with a working drive.
2. Use the up and down arrow keys to highlight the Rebuild option in the main
menu and press the Enter key to select it. The utility displays the drive
matrix, showing the drives and their status.
3. Use the up and down arrow keys to highlight a drive with a FLD (failed)
status and press the Enter key to select it.
4. A pop-up window appears, similar to the screen shown in Figure 7–32. The
utility gives you the option of formatting the replacement drive prior to
rebuilding the information from the failed drive. Press the enter key to select
No to rebuild a drive without formatting, or highlight and press enter to
select Yes to rebuild a drive after formatting. A status bar appears indicating
either formatting or rebuilding. After formatting, the utility automatically
begins rebuilding the drive.
5. When the rebuild progress bar displays 100%, press any key to continue. The
main menu appears.
Figure 7–32 Choose Whether to Format Before Rebuilding