User`s manual
Bit(s)
Designation
00,01
(Maintenance)
02,03
-
04,05
Extended Address
Read
06,07,08
-
09,10
Register Selection
Code
11-14
Asynchronous
Line
Card
Registers
15
Control Strobe
Table 3-4
Line
Control Register Bit Assignments
(For Asynchronous Line
Cards)
Function
Unused
For the secondary register selected by SRS
00-03
and
08-11,
these bits display the contents
of
bits
16
and 17, respectively. This enables the program
to read the extended address bits
of
the current
address and control table base address secondary
registers.
Unused
For the line number selected by SRS
00-03,
the
code bits determine which Asynchronous Line
Card register
is
written into
at
LCR
15
set time.
There are four registers associated with each line
and they are called
"Primary,"
"Format,"
"Baud
Rate,"
and "Maintenance" registers. Descriptions
of
the register bits are found
in
LCR
11-14.
Cleared by Initialize.
This
is
the path provided for access to the line card
registers. Loading
of
a register occurs at
LCR
15
set time and
is
dependent on the line number
selected by
SRS
00-03,
and the register selection
code set
in
LCR
09-10.
Each line has four 4-bit
registers associated with it, designated as:
"Primary,"
"Format,"
"Baud Rate," and
"Maintenance." These registers are cleared by
Initialize.
Bit
assignment description
of
the
registers follows
LCR
15
functional description.
When
set to a one, strobes LCR 11, 12, 13, 14 into
control storage for the register selection code set
in
LCR
09-10
and the line specified by SRS
00-03,
then clears itself.
May
be set at the same
time
as
the LCR bits that it strobes into storage
for the selected register.
3-16
Read/Write
-
-
Read only
-
Write
Write
Write