Specifications

68 Troubleshooting and Diagnostic Procedures
Table 5–1 (Cont.) Troubleshooting Table
Problem Possible Cause Corrective Action
In a newly installed
system or in a system
that has just had the
Q22-bus hardware
reconfigured, the
system hangs or drops
off the VAXcluster
shortly after the
DECvoice ACP
OPCOM "starting"
message is displayed.
Invalid Q22-bus
configuration.
For information about configuring
the Q22-bus, see Section 1.3 in this
manual.
NOTE
The DECvoice device driver (VXDRIVER) currently supports only
the MicroVAX-II processor. Do not attempt to use the driver on
any other VAX processor.