Specifications
Troubleshooting and Diagnostic Procedures 65
Table 5–1 (Cont.) Troubleshooting Table
Problem Possible Cause Corrective Action
On VAX/VMS V5.0 or
V5.0-1, the WINDOW_
SYSTEM is zero.
Change the WINDOW_SYSTEM
sysgen parameter to 1, and reboot
the system. Refer to the VAX/VMS
SYSGEN manual for information
on how to change this parameter.
Run AUTOGEN to reset the
SYSGEN parameters, and reboot
the system by typing the following:
$ @SYS$UPDATE:AUTOGEN
GETDATA REBOOT
FEEDBACK
SYSGEN parameter
STARTUP_P1 is set to
"MIN"
Set STARTUP_P1 to " " to allow
the DECvoice device to configure,
and reboot the system.
The DECvoice CSR is
set incorrectly.
Run VMS SYSGEN, and type:
SYSGEN> SHOW/UNIBUS
The show unibus command displays
the addresses and values of CSRs
that are seen on the Q-bus.
Remove the first module that is
not seen and verify the CSR switch
settings. For information on setting
the CSRs, see Chapter 1, Section
1.2. Check the module for wrong
switch settings and incomplete
switch closure. Toggle the switches
back and forth once to ensure
complete switch closure.