Technical data
Technical Specifications
A-13
Component Possible Failures Result
CPU temperature
sensing
The temperature exceeds 72 °C
(161.6°F).
Backup fans activate without
warning.
If the temperature drops below 70
°C the backup fans are turned off.
The temperature exceeds the
warning level (>75 °C; >167°F).
A warning message appears and a
warning beep sounds. If the
temperature exceeds the warning
level for more than five minutes, the
server automatically shuts down.
The temperature exceeds the upper
limit (>80 °C; >176°F).
The server automatically shuts
down.
Power supplies
present
The incorrect number of power
supplies are present with good
status in the server.
A message displays indicating the
number of power supplies present
in the server.
Power supply
failure
The temperature exceeds the upper
limit or the voltages are out of range.
Power supply shuts down, an error
message displays, and a beep
sounds.