Technical data

Troubleshooting
4-11
DIGITAL Server 5220
Server Status Messages
Component Possible Failures Result
Main logic
board voltages:
+12, +5, +3.3,
and -12V
The voltages are outside of the
power good range.
An error message displays
and a warning beep sounds.
The voltage exceeds the upper
limit.
The server will shutdown after
5 minutes.
The voltage falls below the
lower limit.
A warning message displays
and a warning beep sounds.
Fans 1, 2, 3, 4 The primary fans (fans 1 and 3)
fail.
The redundant fans will
activate.
The primary fans (fans 1 and 3)
and redundant fans (fans 2 and
4) do not operate.
The server will shutdown after
10 minutes.
Fan 5 The rear fan fails. A message displays and a
warning beep sounds.
CPU module
voltages
The voltages are outside of the
power good range.
A message displays and a
warning beep sounds.
The voltage exceeds the upper
limit.
A warning message displays
and a warning beep sounds.
The voltage falls below the
lower limit.
A warning message displays
and a warning beep sounds.
CPU failure Internal
Over temperature
An error message displays
and a warning beep sounds.
Usually caused by a fan
failure and the result is that
the server shuts down.
CPUs present The incorrect number of CPUs
are present in the server.
A message displays indicating
the number of CPUs present
in the server.
continued