Technical data

FRU Replacement
5-54
Removing and Replacing the Storage Backplane
1. Turn off the server.
2. Unlock and remove the right side panel.
3. Record all cable configuration information.
4. Disconnect all cables and terminators.
5. Before removing hot swap drives, record how they are configured.
6. Remove all devices connected to the storage backplane.
7. Remove the ten screws.
8. Remove the storage backplane from the chassis.
9. Configure the J181 jumpers located on new storage backplane so they are
identical to settings on storage backplane being replaced. Also configure
jumper cables and terminators as they were previously configured on the
storage backplane being replaced.
10. Install the new storage backplane into the chassis.
11. Reinstall and tighten the ten screws securing the storage backplane in
chassis.
12. Using the configuration information recorded in step 5, replace the hot swap
drives.
13. Using the cabling information recorded in step 3, reconnect the cables and
terminators.
14. Replace and lock the right side panel.