Technical data

SCSI Device Configurations
7-2
SCSI Configuration Guidelines
The SCSI controller has two buses, Channel 1 and Channel 2, which are
typically used as follows:
Location Mode SCSI
technology
Bus
Speed
Max.
Devices
Max. Bus
Length
Internal
channel 1
Single-
ended
Wide Ultra
SCSI
40 Mbytes/s 8 1.5 m
External
channel 2
LVD Wide Ultra2
SCSI
80 Mbytes/s 16 12 m
Both ends of each SCSI bus must be terminated. The main logic board
termination is set automatically. The other termination on Channel 1 is set
on the storage backplane.
External SCSI connections must be to the second SCSI bus (Channel 2).
Use the SCSI knockouts at the rear of the server and the supplied SCSI
cable.
The Channel 2 bus length is measured from the main logic board (with
termination enabled) Channel 2 connector to the end of the external bus.
All devices on a SCSI bus require a unique SCSI ID. SCSI ID 7 is assigned
to the SCSI controller.
If a single-ended device is added to a bus with LVD devices, the bus
becomes single-ended.