Specifications

6.1 Bad Power or Control Panel FIPs
6.1 Bad Power or Control Panel FIPs
Explanation: A power or control panel malfunction can cause a failure of the
normal power up activities. Because the control panel is inoperative, there are
no error messages.
When the printer is working properly, you can see and hear the following
events after the power is turned on:
Sounds Air wooshing from the exhaust fan, high-pitched whine from the scanner
motor, low-pitched rumble from the main motor and gear train.
Control
panel
Various indicators light as the self test runs, the "Warming Up" message
appears for approximately 200 seconds, and the "READY/IDLE" message
appears at the end of the power-up process.
Action The main motor turns (rounding) the paper path rollers for approximately
six seconds. If the covers are removed, you can see the fuser heater
glowing.
Review the following two sets of symptoms and choose the one that describes
the malfunction:
Symptom 1: The following symptoms indicate a working print engine with a
malfunctioning control panel circuit:
At power up, the rounding cycle completes
The fusing unit gets warm
The engine board test pattern prints.
The control panel message is blank, hung, unreliable, or ambiguous.
Action: Do the following to fix a control panel problem:
1. Make sure that the control panel cable connector is properly plugged into
the J131 connector on the video controller board. See Section 9.2 for the
connectors location and Section 2.1.1 for a block diagram.
2. Swap the following FRUs:
Video controller board
Control panel
DC control board
6–2 Power and Control Panel FIPs