Specifications

5.1 Preliminary Information
5.1 Preliminary Information
Before using the start FIP, do the following:
Record the symptoms, then recycle/reboot the printer.
Do all steps of the start FIP shown in Table 5–1.
Follow the FIPs in order. The printer is not fixed until you complete the
start FIP with no errors.
After fixing the original malfunction, perform the TCC procedures listed in
Section 5.3 to make sure no other problems exist.
Keep the following in mind when the FIP tells you to check a signal or
power supply voltage:
Unless otherwise stated, all voltage readings should be within ±5% of
the stated value.
Voltage level ‘‘low’’ means 0 to +0.5V.
Voltage level ‘‘high’’ means 5V ±0.5V.
The bar over a signal name shows that that signal, when
asserted, is low.
5.2 Start FIP
See Table 5–1 to begin the DEClaser 5100 printer FIP. If the symptoms change
or the troubleshooting path is not clear, go back to the beginning of the start
FIP.
5–2 Start FIP and Total Call Concept